top of page

9 Signs Your Generator Needs Servicing

Nov 3
6 min read

Your generator needs servicing or repair if it's slow to start, skips or fails it’s weekly self test, shows a fault code, makes new noises, smokes, leaks, or delivers power that surges and flickers. On Vancouver Island, add salt air corrosion, rodent nests, and batteries that quietly die over summer. Catch these early and the next windstorm is a non-event.



Here's the thing about generators: they spend 99% of their lives sitting in the side yard doing nothing, and then they're expected to perform flawlessly at 2 a.m. in a November gale. That's a lot to ask of any machine. The good news is that most generators tell you something's wrong well before they leave you in the dark. You just have to know what to look and listen for.


Why Generators Fail When You Need Them Most

Generators rarely fail from overwork. They fail from sitting. Batteries lose charge, fuel degrades, seals dry out, and critters move in. Because most of the work happens during Island outage season, roughly November through February, small problems that developed over a quiet summer tend to show up at the worst possible moment.


Add in our coastal conditions (salty air, damp winters, and the occasional uninvited mouse family) and it's easy to see why a generator that ran perfectly last year might not this year.


9 Signs Your Generator Needs Repair or Servicing


1. It's slow to start, or won't start at all

A hard start is the most common early warning. On standby generators, the starting battery is the usual suspect, especially if the unit is several years old. Other culprits include a failing starter, valves out of adjustment, fuel regulator vent plugged, fuel delivery problems, or worn spark plugs. If it cranks slowly or clicks without turning over, get it checked before you actually need it.


2. It skipped (or failed) its weekly exercise

Most standby generators run a short self-test on a set schedule, often weekly. If you can't remember the last time you heard yours fire up, or the controller shows that the exercise cycle failed, that's a red flag. A generator that can't pass its own test won't pass the real one either.


3. There's a warning light or fault code on the controller

Fault codes exist for a reason. Low oil pressure, overcrank, overspeed, and low battery codes all point to specific problems. It's tempting to clear the code and move on, but repeatedly resetting a fault without finding the cause can turn a small repair into a big one. Write the code down and call a technician.


4. It's making new noises

You know what your generator normally sounds like. Knocking, grinding, rattling, squealing, or a rough, uneven idle are all signs that something has changed: worn bearings, loose components, a slipping belt, or internal engine trouble. New noises rarely fix themselves, and they usually get louder and more expensive the longer you wait.


5. It's smoking

A little vapour on a cold start can be normal. Ongoing smoke isn't. Black smoke often points to a fuel or air-intake problem, blue smoke to burning oil, and white smoke to moisture or coolant where it shouldn't be. Whatever the colour, persistent smoke means the engine needs a professional diagnosis.


6. You see puddles or smell fuel

Oil, coolant, or fuel under or around the unit means a seal, hose, or fitting has failed. Leaks also attract dirt and can damage nearby components. If you smell fuel or gas near your generator, shut it down, keep ignition sources away, and call for service right away. That one isn't a wait-and-see situation.


7. The power it produces surges, dips, or flickers

Lights that pulse or brighten and dim while running on generator power point to voltage regulation, governor, or load issues. Unstable power isn't just annoying; it's hard on electronics, appliances, and anything with a motor or a circuit board. If your house acts strangely on generator power, have it tested under load.


8. The transfer switch isn't doing its job

Your automatic transfer switch is what moves your home from grid power to generator power and back again. If the generator runs but the house stays dark, or the switch won't transfer back once BC Hydro restores power, the problem may be in the switch, the controls, or the wiring between them. This is electrical work, so leave it to a licensed electrician.


9. Corrosion, critters, or crud

Walk around the unit. Rust on the enclosure or terminals, chewed wiring, nesting material, wasp nests, or blackberry vines making a run at the air intake all affect performance. Coastal properties see corrosion faster thanks to salt air, and rural properties are prime real estate for rodents looking for a warm, dry winter home.


And one bonus sign: if you can't remember when it was last serviced, it's probably overdue. Your owner's manual lists the manufacturer's recommended interval.


What You Can Safely Check Yourself (and What You Can't)

Some checks are fair game for homeowners. Others should be left to a pro, because they involve fuel, high voltage, or both.


Safe for most owners:

  • Confirm the weekly exercise is happening, and note any messages on the controller display.

  • Keep the area around the enclosure clear of vegetation, snow, firewood, and debris, following your manufacturer's clearance guidelines.

  • Look for leaks, rust, or signs of nesting from the outside of the unit.

  • Check oil level, coolant reservoir level, and make sure the fill caps are tight.

  • On portable generators, check oil level and fuel condition as described in the owner's manual.


Leave to a licensed professional:

  • Anything inside the transfer switch, electrical panel, or generator's electrical connections.

  • Natural gas or propane line work, which requires a licensed gas fitter in BC.

  • Diagnosing fault codes, load testing, and internal engine repairs.


Safety note: Never run a portable generator indoors, in a garage, or near open windows: carbon monoxide can build up quickly and it's odourless. And never "backfeed" a generator into your home through a dryer or stove outlet. It can energize the lines outside your house and seriously injure BC Hydro crews working to restore power. A properly installed transfer switch or interlock is the safe way to connect a generator to your home.


Repair or Replace: When Is It Time for a New Generator?

Most generator problems are repairable, and a well-maintained unit can give many years of service. Replacement starts to make more sense when major repairs keep stacking up, parts are hard to source for an older model, or your home has simply outgrown the generator you have.


That last one sneaks up on people. If you've added a heat pump, an EV charger, or a hot tub since your generator was sized, it may no longer cover the loads you care about during an outage. (If that's you, our post on whether your electrical panel can handle an EV charger, heat pump or hot tub is worth a read too.) A technician can tell you whether a repair, a resize, or a replacement makes the most sense. Our residential generator and commercial generator pages cover what a new installation involves.


Generator Repair on Vancouver Island: Plan Ahead

Island life comes with a few extra wrinkles. Parts often come over on the ferry, so specialty components can take longer to arrive than they would in Vancouver, and demand for generator service spikes the moment the first big storm rolls through. The smart move is to book a check-up in early fall, when there's time to order parts and fix problems before outage season gets going.


If any of the signs above sound familiar, don't wait for the next windstorm to find out how serious it is.


Frequently Asked Questions


How do I know if my generator battery is bad?

Common signs include slow or sluggish cranking, a clicking sound without the engine turning over, a low-battery fault on the controller, or a failed weekly exercise. Visible corrosion on the terminals is another clue. A technician can load-test the battery and charging system to confirm whether it needs replacing.


Is it safe to keep running a generator that's showing a fault code?

It depends on the code, but it's best not to assume. Some faults, like low oil pressure or overspeed, are designed to shut the generator down to prevent serious engine damage. Repeatedly resetting and restarting without fixing the cause can make the problem worse. Note the code and have a technician diagnose it.


Can a generator be repaired after sitting unused for a long time?

Usually, yes. Generators that sit for a year or more often need a fresh battery, new fuel (for portable units), filter changes, and a full inspection for corrosion, leaks, and pest damage. Starting one that's been neglected without checking it first can cause more damage, so a professional once-over is worth it.


What's the difference between generator servicing and generator repair?

Servicing is preventive: oil and filter changes, battery checks, and inspections done on a schedule to keep things running. Repair is fixing something that has already gone wrong, like a failed starter, a leak, or a faulty transfer switch. Regular servicing is the best way to keep repair bills small and infrequent.


Noticed one of these signs, or just can't remember the last time your generator had a check-up?


Get in touch with the Osprey Electric generator team in Parksville or Campbell River and we'll help you get it storm-ready.

 
 